417A910
USA Only
– Rugged, cost effective medical safety analyzer
– Large color display and easy to use interface
– Full range of medical electrical safety tests to NFPA-99
– 10 lead leakage patient testing
– Tests and fault conditions can be selected with a single key press
– Accurate high current, low energy earth bond testing
Patient lead leakage testing in accordance with NFPA-99
Accurate high current, low energy ground continuity testing
Color display with color coded user interface
Fast step-through of test routines and manual control of fault conditions
The SafeTest 99 is a simple, rugged and cost-effective medical safety analyzer for general electrical safety and patient lead testing. With a large color display and a color coded user interface, it’s easy to select the required test at a touch if a button.
The SafeTest 99 is perfect for high volume testing of medical and laboratory equipment, with or without patient leads. Thanks to the easy to use interface and simple layout, and a fast selection of test routines, testing has never been so easy and dependable!
Compact and portable with a full range of safety tests in accordance with NFPA-99, the SafeTest 99 enables compliance and reduces downtime in medical and laboratory equipment.
Full manual control offers the benefit of executing only those specific tests that are required and provide the user with full control of the power cycles, making testing simple, easy and fast.
An automatic warning of secondary ground paths ensures users are made aware when invalid readings are made, thus ensuring correct and accurate test results first time, every time.
Accessories
All Accessories
All Accessories
Ground Continuity | |
---|---|
Method | 2 wire ZAP technique |
Test Current | >± 200mADC into 2Ω |
Max Test Voltage | 4-24Vrms o/c |
Measuring Range (low range) Resolution | 0.001 – 0.999Ω 0.001Ω |
Measuring Range (mid range) Resolution | 1.00 – 9.99Ω 0.01Ω |
Measuring Range (high range) Resolution | 10.0 – 19.9Ω 0.1Ω |
Accuracy | ±1% of value, ± 5mΩ |
Circuit Protection | Test inhibited if ≥ 30VAC or DC at 4mm inputs |
Powered Leakage Measurements | |
---|---|
NFPA-99 | Ground leakage Chassis leakage (Touch Current) Patient lead leakage |
Measuring Range | 0.1 – 9999μA |
Measurement/Display Resolution | 0.1μA |
Accuracy | ± 2%, ±5μA |
Mains Reversal | Soft key |
Single Fault Conditions Open Neutral | Via soft key |
Open Ground | Via soft key |
Voltage Measurement | |
---|---|
Application | H-N, H-G, N-G and touch voltage (IEC 61010) |
Range | 0.0V – 300VAC |
Resolution | 0.1Hz |
Accuracy | ± 2% ± 5 digits (between 10V – 270VAC) |
Mains Frequency | 45.0 – 66.0Hz |
EUT Load Current Measurement | |
---|---|
Range | 0.0A – 20.0A |
Resolution | 0.1A |
Accuracy | ±5% ± 2 digits |
Power Source | |
---|---|
Maximum Current Rating | 20A @ 120V / 16A @ 230V |
Duty cycle (@70°F ambient) | 16A to 20A, 3 min. on/ 10 min. off 10A to 15A, 3 min. on/ 5 min. off 0A to 10A, continuous |
Environmental | |
---|---|
Operating temperature | 32 to 104°F |
Humidity | 0 -98% Relative humidity, no-condensation |
Storage temperature | 14 to 122°F |
Altitude | 0 – 2185 yards |
Ingress Protection | IP 40 |
Operating pollution degree | 2, according to IEC 60529 |
Applied Parts Connection Box | |
---|---|
Size (L x W x D) | 6.1 x 2.6 x 1.1” (not including flying lead) |
Weight | 0.33lbs |
Rating | Category I |
Environmental Protection | IP 40 |
Impact rating | 5J |
Meets the safety standard | BS EN 61010-1:2010 Pollution degree 2 |
Voltage rating (maximum) | 230Vac |
General Specification | |
---|---|
Weight | 2.5lbs (unit) 5lbs (complete with accessories) |
Size (L x W x D) | 9 x 6 x 4” |