Defibrillator Analyzer / External Pacemaker Analyzer / ECG Arrhythmia Simulator
The Rigel 344 defibrillator analyzer combines the complete testing functions of a defibrillator tester, an external pacemaker analyser, and a true 12-lead ECG patient simulator into one compact, lightweight, and easy to use instrument.
No other defibrillator analyzer delivers the performance testing power of the Rigel 344. This defibrillator analyzer will test both Mono and Bi-phasic defibrillators as well as AED (Automatic Electronic Defibrillator) and all external pacemakers including transcutaneous and transvenous.
The built-in user selectable test loads eliminate the need to carry extra modules to test the transcutaneous pacers. The Rigel 344 defib analyzer delivers unsurpassed biomedical testing capabilities in one instrument.
|
THREE IN ONE TESTER |
|
Small and Lightweight |
|
Versatile
|
Measurements:
Included with the Rigel 344 Defibrillator Analyzer:
DEFIBRILLATOR TESTER
Tests All Defibrillators - Semi -Automatic, Automatic, and those with Bi-Phasic Waveforms.
Measures - Energy, Peak Voltage, Peak Current, and Cardio Sync. Time.
Storage and Playback of Output Waveforms.
Energy Measurement
Load - 50 Ohms +/- 1%
Range (High) - 900 Joules, Res. 1J.
Resolution - 1 Joules
Range (Low) - 0 – 100
Resolution - 0.1 Joules.
Accuracy - +/- 2% of the Reading
Plus 1J for Hi Range or
Plus 0.5J for Low Range.
Maximum voltage - 5200
Maximum Current - 100 Amp (H)
Sync. Time - 0-250 ms.
Waveform Output
Real Time - Output 1000: 1
Stored - Discharge waveform expanded 200:1 and is repeated 8 seconds. It can be viewed through the paddles and through the ECG High Level Output.
PACEMAKER ANALYZER
Tests All External Pacemakers – Transthoracic and Transvenous Pacers.
Measures - Amplitude, Rate, Pulse Width, Pulse Energy, Sensed and Paced Refractory Periods.
50 and 60 Hz Immunity Tests.
Transthoracic Test Load - Fixed 50 Ohm or 12 User Selectable Loads to 1000-Ohms.
A / V Pacer Test Load - 500 Ohms.
Transcutaneous
Test Load - 50 Ohms (Fixed) and Variable 100 to 1000 Ohms user selectable.
Current - 1 to 200 mA
Accuracy - +/- 5% +. 5 mA
Pulse Width - 0.5 to 80 ms.
Accuracy - +/- 1% +.1 ms.
Refractory - 20 – 500 ms
Accuracy - +/- 2 % or +10ms
Atrial and Ventricular
Test Load - 500 Ohms +/-1%
Current - 1 to 25 mA
Accuracy - +/- 5% +. 5 mA.
Pulse Rate - 30 to 800 ppm.
Pulse Width - 0.5 to 80 ms.
Accuracy - +/- 1% +.1 ms.
Refractory - 20 – 500 ms
Accuracy - +/- 2 % or +10ms
Immunity Test - 50/60 Hz
ECG SIMULATOR
Tests All ECG Equipment.
12 lead ECG. User selectable Rates and Amplitudes.
Performance Waveforms - Sine, Square, Triangle & Pulse
12 Arrthymia Waveforms
ECG - Normal Sinus Rhythm
Rate - 30, 60, 90, 120, 240 BPM
Performance - Sine, Square, Triangle and Pulse Rate: 0.5 1, 2, 10, 15, 20, 25, 40 Hz.
Arrhythmias - VFBC, VFBF, VTAC, AFIB PVC, PVC1, PVC2, BGY, RBB AFIB, ATRFT, NSR.
Waveform Output - 12 Lead ECG and Paddle and HI level Output Jacks.
General
Power Requirements - Two 9-Volt Alkaline Battery or AC adapter.
Dimensions - 25.4 x 27.9 x 5.7 cm
Weight - 1.9 Kg
Accessories
Standard - AC Adapter, Universal Paddle Adapter, User Manual, Shrouded Banana Plugs (set of 2), Certificate of Calibration. Optional:
Carrying Case, Paddle Adapters for various manufacturers.