Rigel 344 Defibrillator Analyzer

Rigel 344 Defibrillator Analyzer

 

Defibrillator Analyzer / External Pacemaker Analyzer / ECG Arrhythmia Simulator
The Rigel 344 defibrillator analyzer combines the complete testing functions of a defibrillator tester, an external pacemaker analyser, and a true 12-lead ECG patient simulator into one compact, lightweight, and easy to use instrument.

No other defibrillator analyzer delivers the performance testing power of the Rigel 344. This defibrillator analyzer will test both Mono and Bi-phasic defibrillators as well as AED (Automatic Electronic Defibrillator) and all external pacemakers including transcutaneous and transvenous.

The built-in user selectable test loads eliminate the need to carry extra modules to test the transcutaneous pacers. The Rigel 344 defib analyzer delivers unsurpassed biomedical testing capabilities in one instrument.

 

 

THREE IN ONE TESTER

Small and Lightweight

Versatile

 


Measurements:

  • Measures: Energy, Peak Voltage, Peak Current, and Cardio Sync. Time
  • Storage and Playback of output waveforms
  • Tests all External Pacemakers - Transthorasic, Transvenous, and AV Pacers
  • Measures: Amplitude, Rate, Pulse Width, Pulse Energy, Sensed and Paced Refractory Periods
  • 50 and 60 Hz Immunity Tests
  • Transthorasic Test Loads: Fixed 50 Ohm or 12 User Selectable Loads to 1000 Ohms
  • A / V Pacer Test Load: 500 Ohm
  • ECG Simulator:
  • Tests all ECG Equipment
    • True 12 lead ECG, User Selectable Rates and Amplitudes
    • Performance Waveforms: Sine, Square, Triangle, and Pulse
    • 12 Arrhythmias

 

Customer Comments

No comments have been made about this product. Be the first to let us know what you think.

Knowledge Base

You must be registered to view Knowledge Base articles related to this product. Please register or log-in to view these articles.

Key Features

  • Intuitive Menu Driven Operation
  • Battery or AC Operation
  • Large 4-line LCD
  • Simultaneous Display of All Test Measurements
  • Print function
  • RS 232 Interface
  • Mono, Bi-Phasic and AED’s
  • External Pacemaker tester
  • Variable test loads
  • True 12-lead ECG simulator

Included with the Rigel 344 Defibrillator Analyzer:

  • 12 month certificate of calibration
  • Operation Manual
  • Universal Paddle Adaptor
  • 11 Applied part adaptors
  • 2 sets of banana plugs
  • Hard plastic carry case

Downloads

Please feel free to download any of the documents associated with this product.

Technical Specification

DEFIBRILLATOR TESTER

Tests All Defibrillators  - Semi -Automatic, Automatic, and those with Bi-Phasic Waveforms.
Measures - Energy, Peak Voltage, Peak Current, and Cardio Sync. Time.
Storage and Playback of Output Waveforms.

Energy Measurement
 
Load - 50 Ohms +/- 1%
Range (High) - 900 Joules, Res. 1J.
Resolution - 1 Joules
Range (Low) - 0 – 100
Resolution - 0.1 Joules.
Accuracy - +/- 2% of the Reading
     Plus 1J for Hi Range or
     Plus 0.5J for Low Range.
Maximum voltage - 5200
Maximum Current - 100 Amp (H)

Sync. Time - 0-250 ms.

Waveform Output

Real Time - Output 1000: 1
Stored - Discharge waveform expanded 200:1 and is repeated 8 seconds. It can be viewed through the paddles and through the ECG High Level Output.

PACEMAKER ANALYZER

Tests All External Pacemakers – Transthoracic  and Transvenous Pacers.
Measures - Amplitude, Rate, Pulse Width, Pulse Energy, Sensed and Paced Refractory Periods.
50 and 60 Hz Immunity Tests.
Transthoracic Test Load - Fixed 50 Ohm or 12 User Selectable Loads to 1000-Ohms.
A / V Pacer Test Load - 500 Ohms.           

Transcutaneous

Test Load - 50 Ohms (Fixed) and Variable 100 to 1000 Ohms user selectable.
Current - 1 to 200 mA
Accuracy - +/- 5% +. 5 mA
Pulse Width - 0.5 to 80 ms.
Accuracy - +/- 1% +.1 ms.
Refractory - 20 – 500 ms
Accuracy - +/- 2 % or +10ms

Atrial and Ventricular

Test Load - 500 Ohms +/-1%
Current - 1 to 25 mA
Accuracy - +/- 5% +. 5 mA.
Pulse Rate - 30 to 800 ppm.
Pulse Width - 0.5 to 80 ms.
Accuracy - +/- 1% +.1 ms.
Refractory - 20 – 500 ms
Accuracy - +/- 2 % or +10ms
Immunity Test - 50/60 Hz
 
ECG SIMULATOR

Tests All ECG Equipment.
12 lead ECG. User selectable Rates and Amplitudes.
Performance Waveforms - Sine, Square, Triangle & Pulse
12 Arrthymia Waveforms

ECG - Normal Sinus Rhythm
Rate - 30, 60, 90, 120, 240 BPM
Performance - Sine, Square, Triangle and Pulse Rate: 0.5 1, 2, 10, 15, 20, 25, 40 Hz.
Arrhythmias - VFBC, VFBF, VTAC, AFIB PVC, PVC1, PVC2, BGY, RBB AFIB, ATRFT, NSR.
Waveform Output - 12 Lead ECG and Paddle and HI level Output Jacks.

General

Power Requirements - Two 9-Volt Alkaline Battery or AC adapter.
Dimensions - 25.4 x 27.9 x 5.7 cm
Weight - 1.9 Kg

Accessories 
    
Standard - AC Adapter, Universal Paddle Adapter, User Manual, Shrouded Banana Plugs (set of 2), Certificate of Calibration. Optional:
Carrying Case, Paddle Adapters for various manufacturers.

Knowledge Base

Product Matrix

The Product Matrix allows you to compare the features of up to 5 products. Simply check the box next to the products you wish to compare then select the 'Compare Products' button.

Product Enquiry

Contact Information

indicates required field
Title*
Please type in the validation code from the image (case sensitive).

Additional Information (optional)

 
Site engineered by NorthBloc