Rigel 333 Patient Simulator

Rigel 333 Patient Simulator

Universal Medical Patient Simulator

The Rigel 333 Patient Simulator is a powerful, comprehensive simulator with a number of unique features. This patient simulator provides a true 12 lead ECG signal with 43 arrhythmias, dual blood pressure, respiration, and temperature. The simulator also delivers square, sine, and triangle performance waveforms.

 

True 12-Lead ECG

Small and Lightweight

Accurate

 

Patient Simulations performed:

 

Normal Sinus Rhythm (NSR)

ST Segment

Tall T

Myocardial Infarction

R-Wave Detection

Arrhythmia’s (43)

High Level ECG output

Temperature (YSI400 / 700)

Pacer Waves

IBP (Single / Dual Channel)

Respiration

Apnoea

Performance Waveforms

Pulse Wave

Customer Comments

No comments have been made about this product. Be the first to let us know what you think.

Knowledge Base

You must be registered to view Knowledge Base articles related to this product. Please register or log-in to view these articles.

Key Features

  • Intuitive Menu operation
  • Battery or AC powered
  • True 12-lead ECG simulation
  • 43 Arrhythmia’s
  • IEC and ANSI colour coding
  • Static and Dynamic IBP Simulation
  • Temperature Simulation
  • Respiration
  • Automatic Mode Simulation

Included with the Rigel 333 Patient Simulator:

  • ECG Snap Adaptors
  • Certificate of calibration
  • Instruction Manual
  • Carry Case

Downloads

Please feel free to download any of the documents associated with this product.

Technical Specification

ECG Normal Sinus

Rate - 30, 60, 70, 80, 90, 100,120, 150, 180, 210, 240, 270, 300, 350 BPM
Amplitude - 0.15 to 5mV
High Level Output - 0.5 Volt/mV of Low Level (Lead II)

Performance Waveforms

Sine, Triangle, Square
Rate - 0.1 to 100 Hz
       0.1 to 1 Hz in 0.1 Hz increments
       1 to 10 Hz in 1 Hz increments
       10 to 100 Hz in 10 Hz increments

Tall T Wave

Test Waveform@ 70 BPM
Atrial Pacer
Ventricular Pacer*
Paced Rhythms - Variable from 0.1 to 2mS
R Wave detection - Variable form 10 to 120mS.

Pulse - 2mS Pulse of 1mV amp @ 4 sec intervals

Pacers
ST Segment Analysis - ST Elevation and Depression
                      ST Depression Positive and Negative Slope
                      Myocardial Infarction

Arrhythmias - Atrial
              Ventricular

Blocks

Respiration:
Normal Physiological Simulation:
Base Line Impedance - 250, 500, 750, 100 Ohms
Delta ImpedancE - 0.1, 0.5, 1.0, 1.5 Ohms
Rates - 15, 30, 60, 120 BPM
Apnea - Off, Continuous, 12 Seconds and 32 Seconds Apnea-Bradycardia
Accuracy - Delta Impedance 5% of selection
Rate - 1% of selection


Blood Pressure:
Impedance - 350 Ohms
Excitation - 2 to 16 Volts
Sensitivity - 5uV/V/mmHg
Static - 0, 5, 10, 20, 25, 30, 40, 50, 100, 150, 200, 300 mmHg.
Dynamic - 50/10, 60/20, 70/30, 80/40, 100/60, 120/80 mmHg.
Accuracy - (±2% FS. ±1 mmHg
Synchronized with all normal sinus rates
Physiologically track all arrhythmia selections.

Temperature:
Compatibility - YSI 400/700
25/37 Degree Centigrade
Accuracy - ±1% of reading

General
 
Display - 16 Character 2 Line LCD
Key Pad - 8 tactile keys Ð F1, F2, F3, F4, >, <, ON/OFF, Menu
Output Connectors ECG - 10 Banana Jacks
High Level - 3.5mm Phono Jack
Pressure - 5 contact circular Din
Temperature - 3.5mm Stereo Jack
Physical Size - 140 x 90 x 38 mm
Case - High Impact Plastic
Weight - 285 gram

Power

9 Volt Alkaline/AC adapter (Optional).
Battery Life 40 Hours Continuous.
Display Indicates Low Battery.

Knowledge Base

Product Matrix

The Product Matrix allows you to compare the features of up to 5 products. Simply check the box next to the products you wish to compare then select the 'Compare Products' button.

Product Enquiry

Contact Information

indicates required field
Title*
Please type in the validation code from the image (case sensitive).

Additional Information (optional)

 
Site engineered by NorthBloc