Rigel 311C NIBP Simulator

Rigel 311C NIBP Simulator

Non-Invasive Blood Pressure Analyser

 

The Rigel 311c is an advanced technology battery powered NIBP simulator, which now incorporates innovative calibration tables for all the major monitor manufacturers.

The comprehensive CalTables have been developed and certified by the NIBP monitor manufacturers enabling test results to be immediately and automatically corrected and verified.

In addition, the CalTables can be upgraded quarterly in line with individualmanufacturers’ recommendations to ensure that the Rigel 311c  NIBP simulator is continually capable of testing within specifications.

The Rigel 311c is a lightweight and compact NIBP simulator that has been designed specifically for highly portable applications in biomedical engineering departments in hospitals, health centres and similar medical facilities.

The NIBP simulator incorporates an internal pump for static calibration, leak tests and over pressure tests. Built-in adult and neonate mandrels also eliminate the need for blocks to be used to test blood pressure monitors.

Applications
  • Calibration
  • Production line testing
  • Type Test Approvals
  • Routine Testing of NIBP monitors / modules
  • System Leakage Tests on NIBP systems / cuffs
  • Static Calibration using internal manometer

Related Products

Patient Simulator

SpO2 Simulator

Customer Comments

No comments have been made about this product. Be the first to let us know what you think.

Knowledge Base

You must be registered to view Knowledge Base articles related to this product. Please register or log-in to view these articles.

Key Features

  • Preset Manufacturer’s Calibration Tables
  • User-Defined CalTables
  • Digital Voice-Coil Simulation Engine
  • Lightweight and compact
  • Internal pump
  • Built-in adult and neonate mandrels
  • Battery or AC operation
  • Independent systolic and diastolicpressures
  • High-resolution cuff and pulsepressure waveform display
  • 0.5 mmHg NIBP accuracy
  • Digital Manometer with ±0.1 mmHgresolution

Included with the Rigel 311 NIBP simulator:

  • Internal Rechargeable battery
  • Internal Pump
  • Power Adaptor
  • Certificate of Calibration
  • Instruction Manual
  • Manual Pressure Bulb
  • Cuff Adaptors;
    • Male/Female LUER
    • Male/Female Clippard (Critikon, Siemens)
    • Colder/CPU (Marquette, Protocol Systems)
    • OBAC Quick Release (Hewlett-Packard)
    • Universal 5/32" I.D. hose

Downloads

Please feel free to download any of the documents associated with this product.

Technical Specification

RIGEL 311C SPECIFICATIONS

Rigel 311C NIBP CalTables

  • Datascope Accutorr Plus
  • GE Medical Dash 4000
  • GE Medical Dinamop Pro
  • Philips Medical M3
  • Welch-Allyn Propaq Encore
  • Philips Medical VS1
  • Spacelabs
  • Colin Medical
  • Criticare
  • CAS Medical
  • SunTech

BP Presents Systolic/DiastolicAdult Neonatal

  • 250/190 (212) 150/120 (129)
  • 200/150 (169) 120/90 (99)
  • 150/100 (119) 100/70 (79)
  • 120/80 (95) 80/50 (59)
  • 100/70 (82) 60/30 (39)
  • 80/50 (62) 35/15 (21)
  • 60/30 (42)
Exact Diastolic, Systolic and MAP values are a function of the specific CalTables. TheBP Presets above are taken from the Welch-Allyn Propaq Encore CalTable.

Accuracy                           <± 0.5% of selected target value

Oscillometric Pulse

Pulse Amplitude                   @ MAP 2.0mmHg

Pulse Volume Range             0 to 4.4ml

Pulse Rise Time                   80 msec (minimum)

Pulse Rate

Pulse Rate Range                15-330 bpm

Pulse Rate Accuracy             ± 1bpm, 15-200 bpm

                                           ± 2 bpm 201-330 bpm

Displayed/ Measured Parameters

Dynamic NIBP Cuff Pressure Waveform Measurement Time 0.0 to 180.0 seconds

Maximum Inflation Pressure    0 to 400 mmHg (400.0 mmHg typical)

Inflation Time                         0.0 to 180.0 sec

Inflation Rate                         0 to 999.9 mmHg/sec

Minimum Pressure                0 to 400 mmHg (400.0 mmHg typical)

Deflation Time                       0.0 to 180.0 sec

Deflation Rate                      -0.0 to -999.9 mmHg/sec

Digital Manometer

Pressure Range                      0.0 to 400.0 mmHg

Accuracy                               ± 0.5 mmHg, traceable to NIST

Resolution                              ±0.1 mmHg

Leak Test

Start Pressure                      200 mmHg nominal,

                                          10 to 370 mmHgvia Remote Control

Pressure Drop                      0 to 400 mmHg (400.0 mmHg typical)

Elapsed Time                      60 seconds

High Resolution Manometer    0.0 to 400.0 mmHg (400.0 mmHg typical) 

Knowledge Base

Product Matrix

The Product Matrix allows you to compare the features of up to 5 products. Simply check the box next to the products you wish to compare then select the 'Compare Products' button.

Product Enquiry

Contact Information

indicates required field
Title*
Please type in the validation code from the image (case sensitive).

Additional Information (optional)

 
Site engineered by NorthBloc