Rigel 266 Plus

Compact Manual Electrical Safety Analyser

  • IEC / EN 60601-1
  • Compact and robust enclosure
  • 1-25A Earthbond current
  • Portable & Lightweight
  • Full IEC 60601 Leakage Test
  • Up to 25A AC Test Current
  • Large LCD Display
  • Separate AC & DC Value
Rigel 266 Plus
Click to Request a Demonstration / Quote

Rigel 266 Plus

The Rigel 266 Plus is the most compact electrical safety analyser capable of delivering 25 amps earthbond current and testing in accordance with IEC/EN 60601-1, MDA DB9801, and AS/NZ 3200.

The Rigel 266 Plus safety analyser boasts a large LCD screen and rotary selector, and test routines can be manually controlled for quick and easy testing of medical devices. Single Fault Conditions can be manually introduced to minimise power breaks and reduce test times.

With its compact design and full IEC 60601-1 features, the Rigel 266 Plus safety analyser provides the user with a highly effective and portable test solution.

Rigel 266 Plus

Technical Specification:

AC Earth Bond Test
Open Test Voltage 6V rms nominal
Test Current 1A, 10A, 25A AC
Range 40mohms – 19.99ohms
Resolution 0.01ohms
Accuracy +/- 5% of reading, +/- 2 counts
Measurement 4-wire measurement, floating earth
Insulation Test
Test Voltage 500V d.c. nominal (0.5Mohms load)
Range 100kohms - 100 Mohms
Resolution 0.01 Mohms (<100 Mohms)
Accuracy +/- 5% of reading, +/- 2 counts (100kohms - 20Mohms)
All Leakage Tests
Input Impedance >1Mohm
Frequency Response as per IEC 60601-1 requirements
Accuracy +/- 5% of reading, +/- 10 counts
Range
Earth Leakage 0.04mA – 9.999mA
Enclosure Leakage 0.04mA – 9.999mA
Patient Leakage 0.004mA – 9.999mA
Patient Auxiliary Leakage 0.004mA – 9.999mA
Patient SIP / SOP Leakage 0.04mA – 9.999mA
Patient F-Type Leakage 0.025mA – 9.999mA
F-Type Open Circuit Voltage 110% +/-20% of Mains Input Voltage
Load Test
Measured Load 0.06 - 4kVA
Measured Voltage Mains Supply +/-10%
IEC Lead Test
Test 40V a.c., 1mA nominal
Detects Good, Open, Short, Reverse
Mechanical
Size 310mm x 210mm x 80mm
Weight 4kg
Environmental
Operating 0ºC to 40ºC (non condensing)
Storage -10ºC to 50ºC (non condensing)
Maximum R.H 90%
Part Numbers
350A910 UK (13A)
350A913 Schuko (16A)
350A915 Danish (10A)
350A917 French (16A)
350A918 Czech / Polish (16A)

Med-eCare

Rigel’s Med-eCare Plan is at your service for the entire Rigel Medical range. It covers all typical and unexpected costs associated with calibration and maintenance of your test equipment for the duration of the plan. View Product

Results Printer

The battery powered results printer is one of the most compact printers on the market. View Product

Rigel 601 Calibration Checkbox

The Rigel 601 checkbox accurately replicates the leakage characteristics of equipment designed to IEC 60601-1, providing calibrated leakage values for the verification on electrical safety analysers. View Product

Contact Us