The new Rigel UNI-SiM is truly unique, incorporating 6 vital signs into one handheld simulator. Battery-operated, the UNI-SiM can simulate NiBP, SpO2, ECG wave forms, temperature, respiration and invasive blood pressure simultaneously.
The UNI-SiM is the only simulator capable of undertaking six synchronised vital signs parameters tests, enabling medical device engineers to quickly, easily and accurately perform NiBP, SpO2, ECG, temperature, IBP and respiration functionality tests simultaneously using a single portable instrument.
The battery powered vital signs simulator reduces the time taken to test the correct performance of a wide range of medical devices and equipment used in hospitals, operating theatres and other facilities.
It synchronises the full functionality of Rigel's UNI-SiM and SP-SiM as well as a comprehensive patient simulator (ECG, invasive blood pressure, respiration and temperature) to cut simulation times and deliver cost-saving benefits - engineers no longer need to use a variety of different instruments for testing these functions separately.
Whilst the UNI-SiM incorporates a range of custom settings that include a variety of paediatric and adult NIBP pressures, pulse volume adjustments, heart rate and manufacturer-specific O-curves, the UNI-SiM is fully customisable to meet specific performance test conditions.
The UNI-SiM also utilises new and advanced technologies to maximise the accuracy of each simulation. For example, both electronic and optical SpO2 simulation methods are combined into a single test setup, and manufacturer specific simulation curves are included during NIBP simulation, reducing uncertainties thus improving the test time. Featuring Bluetooth connectivity, simulation test results can be stored within the instrument and printed wirelessly to the rugged battery operated Elite Test and Tag printer.
John Backes, Business Unit Manager for Rigel Medical was interviewed at the Medica Trade Fair 2009 in Dusseldorf. You can view this interview on Rigel Medical's YouTube Channel by clicking here.
■ Synchronised heart rate
Test across all parameters from one centralised heart rate simulation
■ Hand-held
This portable and lightweight unit is ideal for field service technicians
■ Battery operated
Convenient and fast testing without mains power
■ Manual and automatic operation
Choose the operation mode, staying in full control of the test situation
■ Onboard data entry and storage
Store up to 10,000 asset records, making record management simple
■ Custom test protocols
Create your own automatic sequences to automate your PPM procedures.
■ Download / Upload software
Keep up to date with ease
■ Bluetooth communication
Transfer between PC and accessories
■ Barcode / Test and Tag capability
Onsite printing and scanning of barcode labels
| 1 Non-invasive Bloodpressure (NiBP) | |
| Simulation waveform | Oscillometric |
| Integrated Pump | 0 to 350 mmHg user configurable |
| Leak test | user configurable between 0-350mmHg |
| Chronometer | configurable up to 999 secs |
| Digital Manometer | 0 - 410 mmHg |
| Pressure Accuracy | +/- 0.5% FS |
| Pressure Units | mmHg, inHg, kg/cm2, cmH2O, mBar, PSI, inH2O and kPa |
| 2 Oxygen Saturation (SpO2) | |
| Range | 50 to 100% |
| Accuracy | ± 1 bpm |
| Chronometer | test option to test response time SPO2 monitor |
| 3 ECG Arrhythmia Simulator | |
| ECG | full 12 lead simulation including high level output |
| Wave forms | Normal Sinus Rhythm (NSR), ST Elevation, ST Depression, Myocardial Infarction, Tall T |
| Rate | 20 - 300 BPM typed value |
| Performance waveforms | Sine, Square, Triangle, and Pulse |
| Pacer Waveforms | Synchronous Atrial, Asynchronous Atrial |
| Pacer Only | Pacer Pulse rate 60 BPM, Ventricular Pacer rate 70 BPM, Atrial & Ventricular Pacer Heart rate 70 BPM, R Wave Detection |
| Arrhythmia Waveforms | |
| Atrial | Sinus Arrhythmia (SA), Missing beat, Atrial Flutter (AFLT), Atrial Fibrillation (AFB), Paroxysmal Atrial Tachycardia (PAT), Junctional Premature Contraction |
| Atrial Conduction | First Degree AV Block , Second Degree AV Block - Mobitz I, Second Degree AV Block - Mobitz II, Third Degree AV Block , Right Bundle Branch Block (RBB), Left Bundle Branch Block (LBB), Left Anterior Hemiblock |
| Ventricular | Premature Ventricular Contraction - Intermittent Premature Ventricular Contraction - Continuous, Bigeminy, Trigeminy, Ventricular Flutter (VFLT), Ventricular Fibrillation (VFB), Ventricular Tachycardia (VTC), Right Focal PVC |
| 4 Temperature | |
| Simulation | YSI 400 / 700 Static |
| Range | preset at 25, 33, 37and 41°C |
| 5 Respiration | |
| Rates | 5, 10, 15, 30, 60, 120, 180 Breaths per Minute |
| Base resistances | 250, 500, 750, 1000 ohms |
| Apnoea Simulation | 0 - 60 seconds duration 0 - 300 seconds interval |
| 6 Invasive Blood Pressure (IBP) | |
| Channels | 2 channels |
| Static | 0 to 300mmHg. Typed values |
| Dynamic | 0 - 300mmHg for systolic & diastolic |
| 7 General | |
| Operation | Battery cell, insitu charge |
| Battery charger | 110-230VAC, 50/60 Hz |
| Battery life | 4-24 hours testing depending on simulations |
| Memory Capacity | Approx. 10,000 records |
| Communication | Via Blue Tooth |
| Display | Monochrome ¼ VGA full graphics |
| Keypad | Alpha-numeric |
| Weight | <1.5 kg |
| Size (L x W x D) | 270 x 110 x 75 mm / 10.5 x 4 x 3" |
| Operating conditions | 10-30'C, 0-90% RH - NC |
| Storage environment | -15' - +60'C |
| Environmental Protection | IP 40 |