Rigel Medical has introduced a new high performance Electrosurgical Analyser with the emphasis on speed and ease of testing all modern day Electrosurgical devices. The new Rigel 377 utilises a new approach to measuring the high frequency leakage, power distribution and remote plate security testing, ensuring high accuracy and the widest range of built-in resistors. Full colour screen and rotary ensure navigation make the Rigel 377 easy to operate and can provide step by step help to ensure the correct connection to the device under test.

The new Rigel 377 incorporates a range of custom settings that include a variety of test sequences and power distribution curves which make testing fast, easy and accurate. Utilising the large full colour display, built-in memory and data management facilities, the Rigel 377 is the first fully stand-alone diathermy tester that can offer true user friendly operation and operator safety. The large array of internal resistors, ranging from 10-5100Ω in 10Ω steps provide not only the most accurate and detailed power curves, the Rigel 377 also advocates safe working practise by providing all necessary resistors within the enclosure.

The remote electrode monitoring test offers a unique isolated and electronically driven potentiometer to provide accurate and fast testing of alarms. In addition, the Bluetooth-enabled technology allows the wireless connectivity of the tester with PCs and other accessory equipment for fast and convenient downloading of performance data and the uploading of manufacturers’ power curves and manufacturer specific test programs.

Other special features of the Rigel 377 include in-built graphics to display connection diagrams, program settings, power curves, alarm settings, data management and data analyses.

 

Custom Test Settings

The unique colour user-interface provides both graphic as well as numeric representation of the test data. Showing manufacturer specific curves and allowable tolerances, the large colour screen provides instant performance indication.

Use the graphic representation to quickly determine whether the test data meets the set criteria.

Use the numeric representation of the data to analyse parameters such as Peak voltage, crest factor, power and current at each resistance point etc.

 

Remote Electrode Monitoring
Use the rotary encoder to set high and low alarm points as well as controlling the potentiometer, scaling up or down in manual or automatic mode. Then, simply capture the alarm using the dedicated fast key on the screen.
Data will be stored onboard for future traceability.

 

HF Leakage
Individual settings can be selected using the simple configuration template. The settings are automatically translated into a detailed scheme as shown below;
Detailed instructions on the leakage path and connections between each setting are provided in a clear and colour coded overview.

Colour coded connections correspond to the matching connection on the tester.

 

Customer Comments

No comments have been made about this product. Be the first to let us know what you think.

Knowledge Base

You must be registered to view Knowledge Base articles related to this product. Please register or log-in to view these articles.

Key Features

  • Fully compliant with IEC 60601-2-2
    One instrument for full compliance testing offering peace of mind
  • Accurate and Safe
    Utilising full 10kV isolation on all measuring systems
  • Multiple Measuring Devices
    For simpler user test configurations, benefiting speed and ease-of-use
  • High Frequency Leakage
    Easy to connect with onscreen help for each configuration
  • Power distribution curves
    Variable load with full 10kV isoltion from 10 to 5100Ω in 10Ω steps - Accurate, fast, and flexible
  • Remote Electrode Monitoring testing
    Using electronic potentiometer range upto 500Ω in 0.5 Ω steps with high and low alarms
  • Stand-alone
    Not relying on PC or laptop, direct print facility via bluetooth
  • Automatic and manual test sequences
    For fast and effective (repeat) testing
  • Stylish and rugged enclosure
    Small footprint ideal for in-situ testing
  • Graphic colour user interface
    For fast and easy navigation and connection to DUT
  • Future upgrade ready
    Download future upgrades from the web into your tester
  • Prepared for PPM protocols
    Configured for automatic performance testing of a variety of parameters

Applications:

To verify the correct performance of Electrosurgical devices during:

a. Routine testing

b. Type testing

c. Production line testing

Unique training tool for testing on Electrosurgical devices

Downloads

Please feel free to download any of the documents associated with this product.

Technical Specification

Specification
Power measurement                            True RMS value of applied waveform
Power rating                                         0 - 500W (RMS)
Duty cycle                                             100% 0-250W, 50% >250W
Accuracy                                              ±1W or 5% of value
Voltage (peak)                                       0 - 10KV (Peak) - Closed load only
Accuracy                                               ±10% of value.
                                                               Measurement is taken between the active and dispersive
                                                               electrodes with closed load only.
Voltage (RMS)                                        0 - 500V
Accuracy                                               ±2V or 2% of value
Current                                                    0 - 2200mA
Accuracy                                               ±10mA or 2% of value
Crest factor                                            1.4 - 20 (Vpeak / V RMS)
                                                               The higher of the two peak voltage measurements is used for calculation

RMS Bandwidth
Instrumentation only                                30 Hz to 10 MHz (-3 dB)
With loads:                                              30 Hz to 2.5 MHz (-3 dB)
Variable loads                                         10 - 5100Ω, steps @ 10Ω (510 steps)
Accuracy                                                1% of R
Load array                                              Ceramic Resistors (Non inductive)
Measurement delay                                 Foot switch delay selectable between
                                                                200 - 5000mS (10mSec resolution)


RF Leakage (High Frequency Leakage)
Active                                                       From active part to earth
Passive                                                     From plate - receptacle - to earth
Load                                                          Variable see Power Measurement 
                                                                  Fixed 2 x 200Ω / 250 Watt each

Remote Electrode Monitoring
Range                                                        0 - 500Ω, steps @ 0.5Ω steps
                                                                  Motor driven potentiometer
Alarm register                                            High and low, manual confirmation
Ranging                                                      Manual or automatic

 

Output Connectors
Remote foot switch control (CUT)              2 x 4 mm - yellow, Single relay contact
Remote foot switch control (COAG)          2 x 4 mm - blue, Single relay contact
High Frequency leakage                             1 x 4 mm - black (common), 2 x 4 mm - red
Variable load output                                   2 x 4mm (for power measurement)
                                                                   Red = Active, Black = Plate
Fixed load input                                          3 x 4 mm (3 x Blue) (200Ω / 500W)
USB                                                            PC Download / Future PC software

Oscilloscope                                              output 5V/A, 100mA RF current minimum input
Isolation                                                   10kV Isolation between measurement device and enclosure
Low Frequency Filter                            100 Hz filter to avoid low-frequency disturbance or interference
 

Storage and Recall
Memory                                                       Approx 5,000 records
Output                                                         CSV format
Waveform
 

General Specifications
Dimensions                                                 370 X 300 X 204mm
Weight                                                        7 Kg
Operating temperature                               15 °C to 35 °C
Storage temperature                                  0 °C to 50 °C
Mains power                                              115/230 VAC; 48 to 66 Hz, 35 VA

Knowledge Base

Product Matrix

The Product Matrix allows you to compare the features of up to 5 products. Simply check the box next to the products you wish to compare then select the 'Compare Products' button.

Product Enquiry

Contact Information

indicates required field
Title*
Please type in the validation code from the image (case sensitive).

Additional Information (optional)

 
Site engineered by NorthBloc   
© 2010, Seaward Electronic Group Ltd. All rights reserved.